INPUT CHARACTERISTICS: |
|
|
VOLTAGE:
90 - 264VAC |
|
|
FREQUENCY:
47 - 63 Hz |
|
|
INPUT
CURRENT: 6.0 / 3.0A FOR 115 /230 VAC |
|
|
INRUSH
CURRENT: 50A / 70A MAX. FOR 115 / 230 VAC PER MODULE |
| >
SPECIFICATION |
|
|
TEMPERATURE
RANGE : OPERATING 0oC --- 40oC,
STORAGE -20oC --- 70oC |
|
|
HOLD
UP TIME: 12 ms MINIMUM AT FULL LOAD & 90 VAC INPUT-VOLTAGE |
|
|
DIELECTRIC
WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE |
|
|
INPUT
TO FRAME GROUND 1500 VAC FOR 1 MINUTE |
|
|
EFFICIENCY:
63% TYPICAL, AT FULL LOAD |
|
|
POWER
GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms |
|
|
OVER
LOAD PROTECTION: 110 ~ 160% MAX. |
|
|
OVER
VOLTAGE PROTECTION:
+5V 5.7V
~ 6.5V; +3.3V 3.9V
~ 4.3V; 12V 13.3V
~14.3V |
|
|
OVER
CURRENT PROTECTION :
5V,12V,3.3V 130% +/-20% AT FULL LOAD -5V,-12V SHORT CIRCUIT |
|
|
EMI
NOISE FILTER: FCC CLASS B, CISPR22 CLASS B |
|
|
SAFETY:
MEET UL 1950, CSA 22.2 NO/ 950, TUV IEC 950 |
|
|
DIMENSION:
185(D) x 150 (W) x 86(H) mm |